The Common Case: Standard Cylinder and Coil Area
For many bungalows, particularly those with 1-2 bathrooms and standard occupancy, we'll often look at a 200-250 litre unvented cylinder. The crucial factor isn't just the volume, but the internal coil surface area. Heat pumps operate at lower flow temperatures than gas boilers, so you need a much larger coil inside the cylinder to transfer the heat effectively. A typical heat pump cylinder might have a coil area around 3-4 square metres, significantly more than a boiler-spec cylinder. This larger area allows the heat pump to efficiently heat the stored water without excessive run times or needing an oversized heat pump.
- Coil area matters more than volume for heat pumps
- Expect larger coils than boiler cylinders
- Avoids oversizing the heat pump unit